Air Seeder Cart Inspection Form for Pre-Season Checks
Use this routine to inspect an air seeder cart system by system, find the worn parts that cause skips and uneven rates, and record what you fixed.
Key points
- Inspect before calibrating; calibration on worn meters only locks in the problem.
- Check seals and lids for leaks first, since air loss lowers fan pressure and moves seed unevenly.
- Run the cart empty and then with seed, watching every outlet.
- Write down every repair so you can see which parts fail repeatedly.
Tank, lids and seals
Open each tank and look for rust, rodent damage, trapped old seed, and moisture. Old treated seed left in corners can bridge and clog meters. Inspect lid gaskets and seal strips; a lid that does not seal leaks air and lets dust and moisture in. Clean the tanks and vacuum out dust before filling.
Meters and rollers
- Remove the meter cover and look at each roller for rounded flutes, cracks, or chewed edges.
- Check that the roller is the right type for the seed you will plant. Small seeds usually need a different roller from large seeds.
- Look for seed or fertilizer residue, which can corrode metal and cake in damp weather.
- Turn the drive by hand and feel for binding, a loose chain or sprocket, or a slipping clutch.
- Confirm gate or slide settings move freely and return to the same mark.
Worn rollers deliver less than the setting says. If you cannot tell by eye, a catch test will show it; the method is in the Air Seeder Calibration Guide.
Air system
- Check the fan belt or hydraulic motor, hoses and fittings for cracks and leaks.
- Inspect distribution hoses for kinks, sags, and wear points where they rub.
- Look at the primary and secondary headers or towers for cracks and loose lids.
- Clear each opener tube and boot of dirt, nests, or old seed.
- Run the fan at working speed with the tank empty and listen for leaks and unusual noise.
Sensors and electronics
Confirm that blockage sensors, shaft-speed sensors, and tank level or load cells read sensibly. Zero the scales per the manual. A speed sensor that is out by even a few percent distorts the rate on every acre, so check it against a measured distance.
Running test
Fill each tank partly, run the cart with openers raised, and watch every outlet for seed flow. Then lower the openers over a short test strip and dig behind a few to confirm depth and seed placement. This is the place to catch a plugged run before the field does.
Safety
Lock out the hydraulics and fan before reaching into tanks, meters or hoppers. Never climb into a tank with seed flowing or a fan running; seed and treated-seed dust are hazards. Wear a dust mask when cleaning treated seed residue, and follow the seed treatment label for disposal.
Record you can copy
| Field | What to record |
|---|---|
| Date, cart and hours | Machine identification |
| Tanks and lids | Condition, leaks found |
| Meter rollers | Type, wear, replaced |
| Fan and hoses | Repairs made |
| Sensors | Verified, offset noted |
| Test strip result | Skips or plugs seen |
| Inspector sign-off | Name and date |
Authoritative references
- USDA NRCS - planting and conservation practice standards.
- EPA Pesticides - handling and disposal of treated seed.
- Nebraska Pesticide Safety Education - applicator safety training material.