Seed & Input Directory

Drill Calibration Worksheet

Follow this worksheet to calibrate a seed drill in the shop or field, calculate pounds per acre from a catch test, and adjust the setting until it hits your target rate.

Key points

  • A catch test beats the setting chart, because seed size, wheel slip and wear change the real rate.
  • Run the test with the seed lot you will plant, and repeat it until two runs agree.
  • Do a field check by dividing seed used by acres covered.
  • Recalibrate for every species, seed lot and big change in seed size.

What you need

Seed of the lot to be planted, a scale, collection bags or trays for every opening or a sample of them, a tape measure, chalk, a jack or a flat spot, and the drill manual. Set the drill on a firm level surface, check tire pressure, and fill the box to a typical level.

The catch method

  1. Measure the drive wheel circumference by marking the tire, rolling the drill one turn and measuring the distance. Do it under load; tire pressure and sinking change the figure.
  2. Compute acres per revolution = circumference (ft) x working width (ft) / 43,560. Working width is the row spacing times the number of openings.
  3. Choose a number of revolutions that gives a measurable catch, such as 20.
  4. Set the meter or gate to the manual's suggested setting for the seed and rate.
  5. Prime the meter by turning the wheel until seed flows from all openings, then empty the catch containers.
  6. Turn the wheel the chosen revolutions at a steady walk-pace, catching seed from all openings or from a known number of them.
  7. Weigh the catch and, if you caught from only some openings, scale to the full drill.

Calculate the rate

Rate (lb per acre) = total pounds caught / (acres per revolution x revolutions)

Illustrative: a 15 ft wide drill with a 10 ft wheel circumference and 20 revolutions covers 10 x 20 x 15 = 3,000 sq ft = 0.0689 acre. If 2.1 lb is caught, the rate is 2.1 / 0.0689 = 30.5 lb per acre. If the target is 35, increase the setting a little and retest. Make small changes; repeat until two runs fall within a few percent of each other and the target.

Field check

Plant a measured area, such as the first few acres. Weigh seed used (box weight before and after) and divide by acres. If the field rate differs from the catch rate, look at wheel slip in soft ground, speed, and seed bridging. Check the setting again as the box empties.

Common errors

  • Using a wheel circumference measured on hard shop floor but planting in soft soil.
  • Forgetting a plugged opening or a worn flute.
  • Calibrating with a different seed lot, treated versus untreated seed, or a different species.
  • Ignoring the difference between bulk and pure live seed rates; convert as shown in the Germination and Pure Live Seed Calculation Guide.

For drills used in heavy residue see the No-Till Drill Calibration Worksheet; for cover crop seed see the Cover Crop Seeder Calibration Log.

Record you can copy

FieldWhat to record
Drill and dateID, operator
Crop and seed lotSpecies, lot, treated or not
Wheel circumferenceFeet, loaded
Working widthFeet
SettingGate, flute or dial
Revolutions and catchPer run, pounds
Calculated rateLb per acre
Field checkSeed used, acres

Authoritative references