Cover Crop Seeder Calibration Log

Use this log to calibrate your seeder for each cover crop species or mix, record what it actually delivers, and spot drift in rate from season to season.

Key points

  • Calibrate for every new species or mix; a setting that works for rye will not deliver the same pounds of radish or clover.
  • Fluffy, light or mixed seed bridges and separates in the box, so check the rate again after the box is half empty.
  • Write down the setting, the catch and the date every time; the log shows wear and error trends a memory will not.
  • The seed tag and a scale decide the answer, not the setting chart that came with the machine.

Why cover crops need their own log

Seeder charts are written for grain and soybean seed. Cover crop seed differs widely in size, weight and shape: small round brassica seed flows like sand, while oat hulls, hairy vetch pods or fluffy grass seed can bridge over the meter. Mixes also separate as the machine vibrates, so the heavy seed settles and the light seed rides on top. A log catches these problems because each line records what the machine did, not what the chart promised.

The basic catch test

  1. Weigh a known amount of seed into the box and note the seed lot number from the tag.
  2. Set the meter to the chart setting for the nearest crop and record it.
  3. Jack up the drive wheel (or, for a ground-drive drill, use the revolution count your manual gives). Turn the wheel the specified revolutions while catching seed from several openings in bags or trays.
  4. Weigh the catch, convert to an area-equivalent and compare with your target.

For a ground-drive drill: acres covered = wheel circumference (ft) x revolutions x working width (ft) / 43,560. In an illustrative case, a 10 ft circumference, 20 revolutions and 15 ft width cover 3,000 square feet, or 0.069 acre. A 1.3 lb total catch is then about 19 lb per acre. Repeat the test and adjust the setting until two runs agree within a few percent. The full method is in the Drill Calibration Worksheet.

Mixes, species and conditions

  • Calibrate the mix as a mix only if you are going to seed it as a mix. If the species are very different in size, run separate boxes or make two passes.
  • Re-test after refilling and when the box is about half empty, then compare the two catches.
  • Note humidity and seed-lot changes; damp seed and a new lot can change flow.
  • For broadcast or spinner units, record the driving speed and swath spacing as well; see the Broadcast Seeder Calibration Worksheet.
  • Turn the planned rate into pounds using the Cover Crop Seeding Rate Calculator.

Field check

After seeding, weigh seed used and divide by acres seeded. If the field rate is more than about 10 percent away from target, stop and recalibrate. Dig a few quadrats a few weeks after emergence and count seedlings.

Record you can copy

FieldWhat to record
Date and operatorWho calibrated and when
Machine and settingDrill/seeder ID, gate or meter setting, drive speed
Species or mix and lotNames, percentages, tag lot number
Test methodRevolutions, distance, or time used
Seed caughtWeight per run and number of runs
Computed ratePounds per acre, bulk basis
Target rate and differencePlanned rate and percent off
Field checkSeed used per acres, notes on bridging