Seed & Input Directory

Air Seeder Calibration Guide: Meter Catch Test and Rate Check

You will be able to run a stationary catch test on each meter roller, work out the actual pounds per acre, and correct the setting before seed goes in the ground.

Key points

  • Calibrate every seed type and every meter roller you use; a setting that is right for wheat is wrong for canola.
  • Catch tests on a stopped cart only prove the meter; confirm the rate again with acres covered and seed used.
  • Recalibrate after changing seed lot, seed size, treatment, or roller, because flow properties change.
  • Follow the cart manual's calibration crank procedure; the numbers below are illustrative.

Before you start

Inspect the meter housings, rollers, seals and hoses first. Worn rollers or a cracked seal will give a calibration that drifts within hours. Our Air Seeder Cart Inspection Form covers those checks. Use the actual seed you will plant, with any treatment already applied, and fill the meter hopper at least a third full so the head of seed is realistic.

The catch test

  1. Set the meter roller and gate to the manual's starting position for your seed and target rate.
  2. Place the catch tray or bags under the meter outlets (or disconnect the hoses as directed).
  3. Turn the calibration crank the number of revolutions the manual gives for the area you want to simulate, commonly one tenth of an acre at your working width. Prime the meter first and discard that seed.
  4. Weigh what you caught, subtract the container, and repeat at least twice.

Formula: pounds per acre = pounds caught / acres simulated.

Illustrative example: the manual says 100 crank revolutions equal 0.10 acre at your width. You catch 8.2 lb, so the meter delivers 82 lb/ac. Your target is 90 lb/ac.

Adjusting the setting

Roller output is close to proportional to the setting for a given seed, so:

new setting = old setting x (target rate / actual rate)

In the example, 90 / 82 = 1.10, so raise the setting about 10 percent, then catch again. Two matching tests within a couple of percent of each other are a reasonable stopping point.

Multiple meters and tanks

Test each meter separately. Compare outlets on the same meter; if one run is lighter, look for a blocked or kinked hose, not a calibration fault. Where one tank feeds several rows or sections, uneven distribution shows up as stripes, not a rate error.

Field verification

A stationary test does not capture wheel slip, fan speed, or seed shape effects. After the first field, compare:

  • Acres covered by the monitor or GPS.
  • Seed used, found by weighing the refill or by tank level.

Pounds used divided by acres covered should be within a few percent of the target. If it is consistently off in one direction, adjust the speed-sensor calibration or the gate setting, not both at once. A related check for small seeds is in Planter Calibration for Small Seeds.

Common errors

  • Using clean seed for calibration, then planting treated seed that flows differently.
  • Forgetting that seeds per pound varies by lot, so the same weight is a different seed count.
  • Catching seed at fan speeds or tank levels that do not match field use.

Record you can copy

FieldWhat to record
Date and operatorWho ran the test
Seed type, lot, treatmentMatch the seed tag
Meter roller and gate settingStarting and final
Crank revolutions and acres simulatedFrom the manual
Pounds caught (each trial)At least two trials
Calculated lb/acVersus target
Field checkAcres covered and seed used

Authoritative references

Related guides