Seed & Input Directory

Yield Monitor Calibration Log

Use this log to calibrate your combine's yield monitor each season, compare it with certified scale weights and record the settings so your yield maps can be trusted.

Key points

  • Yield maps are used for zones, prescriptions and trials, so errors in calibration spread into later decisions.
  • Calibrate for each crop, and recalibrate if conditions or flow rates change.
  • Verify against a certified scale and record the correction.
  • Check moisture, header, speed and GPS delay settings, not just weight.

What needs calibrating

  • Mass flow: the sensor measures grain flow and converts it to weight. It needs calibration across the range of flow rates you harvest.
  • Moisture: the sensor must match a reliable grain tester.
  • Distance and speed: the ground speed signal and header position sensor.
  • Delay and lag: the time between cutting and measurement.
  • Header width and area: to compute yield per acre correctly.

Follow your manufacturer's procedure, as the steps differ by brand and model.

Typical weight calibration steps

  1. Clean the grain path and sensors. Warm up the combine and monitor.
  2. Start a new calibration load for the crop and variety.
  3. Harvest loads at different flow rates, typically a light, medium and heavy pass, each of a few thousand pounds or more as the manufacturer advises.
  4. Weigh each load on a certified scale, such as an elevator scale or a calibrated weigh wagon, and enter the weights.
  5. Let the monitor calculate the factor.

Illustrative check: the monitor shows 4,820 bushels, and scale tickets show 4,950. The correction factor is 4,950 / 4,820 = 1.027, or about 2.7 percent more than the monitor. Do not use one load to adjust across the board; check that several loads agree.

Moisture

Test grain samples with a good grain tester or the elevator's meter, and compare with the on-board sensor. Adjust the offset if recommended. Moisture affects yield, which is normally reported at a standard moisture content, so use consistent standard moisture settings.

Daily and field checks

  • Check the header height and width settings.
  • Confirm the monitor starts and stops mapping with the header.
  • Look for obvious errors in the map: spikes at ends of rows, zeros, and sudden steps between swaths.
  • Re-check when changing field, moisture, speed range or header.

Cleaning the data

After harvest, filter out start and end delays, turns, overlap and implausible speed or flow. See the precision ag data management guide for file handling, and keep GPS accuracy checked with the auto-steer calibration record. The display setup checklist helps ensure units and boundaries are consistent.

Record you can copy

FieldWhat to record
Date, combine and cropVariety, header width
Calibration loadMonitor weight against scale weight
Flow rateLight, medium, heavy
Correction factorScale divided by monitor
Moisture checkSensor against tester
Delay settingSeconds
Field and notesProblems, conditions

Authoritative references

Related guides