Strip-Till Unit Calibration Worksheet
Use this worksheet to set a strip-till bar's fertilizer metering so you apply the intended pounds per acre, and to check that strips are placed at the right depth and spacing.
Key points
- Fertilizer rate per acre is set by metering output, ground speed and bar width, so check all three.
- Collect and weigh the output over a measured time rather than trusting the controller.
- Banded nutrients are concentrated in a strip, so confirm rate per acre of the whole field, not the strip.
- Recheck after changing product, since density and flow differ.
Basic formulas
Acres per hour = working width in feet x speed in mph / 8.25
Pounds per acre = pounds applied per minute x 60 / acres per hour
Working width equals row spacing times number of rows. For example, 8 rows at 30 inches is 20 feet.
Illustrative: 20 feet at 5 mph gives 20 x 5 / 8.25 = 12.1 acres per hour. To apply 100 pounds of product per acre you need 12.1 x 100 = 1,210 pounds per hour, or about 20 pounds per minute for the whole bar, which is 2.5 pounds per minute per row.
Step by step
- Measure speed over a known distance in the field conditions: 200 feet in 27 seconds gives 200 x 0.68 / 27 = 5.0 mph.
- Set the metering to a trial setting for the product and rate. Dry fertilizer varies with granule size and moisture, so use the chart as a start only.
- Catch test: With the bar stationary, or on a calibration mat, run the meter for a timed period, for example 1 minute, collect from several rows and weigh. Alternatively, drive a measured distance with collectors attached. Liquid systems: collect for a minute and measure ounces, then convert using the product's density.
- Calculate the rate with the formula above, using total output of all rows.
- Adjust the setting and repeat until the rate is within the tolerance you accept.
- Check row-to-row variation: large differences between rows mean plugged lines, worn parts or poor distribution. Fix before applying.
Strip placement
- Measure depth in several locations. Typical settings depend on the soil and crop, so follow your agronomist's advice.
- Check that the strip is located where the planter row will go. Mark and test with GPS guidance or auto-steer.
- Confirm fertilizer outlet position: banded fertilizer too close to the seed can hurt germination. Follow the extension guidance for safe distances and rates for your crop and product.
Common errors
- Using the controller's displayed rate without checking the weight output.
- Calibrating at one speed and operating at another.
- Not recalibrating when the product changes.
- Ignoring a worn or sticky meter.
Convert nutrients correctly: product pounds x analysis percent / 100 = nutrient pounds. Follow your soil test recommendations; see the fertilizer recommendation worksheet, and compare with the spinner spreader calibration for broadcast units.
Record you can copy
| Field | What to record |
|---|---|
| Date and field | Bar, tractor, operator |
| Row count and spacing | Working width in feet |
| Product and analysis | Name, percent nutrients |
| Speed | mph measured |
| Meter setting | Dial, rpm or controller number |
| Output per minute | Pounds or ounces, by row |
| Calculated rate | Pounds product per acre |
| Strip depth | Inches, at several points |
Authoritative references
- NRCS - nutrient management and conservation tillage standards.
- UW Extension Soils, Nutrient Management and Soil Health - fertilizer recommendations and management.
- Agronomic Crops Network Precision Agriculture - application technology.