Seed & Input Directory

Strip-Till Unit Calibration Worksheet

Use this worksheet to set a strip-till bar's fertilizer metering so you apply the intended pounds per acre, and to check that strips are placed at the right depth and spacing.

Key points

  • Fertilizer rate per acre is set by metering output, ground speed and bar width, so check all three.
  • Collect and weigh the output over a measured time rather than trusting the controller.
  • Banded nutrients are concentrated in a strip, so confirm rate per acre of the whole field, not the strip.
  • Recheck after changing product, since density and flow differ.

Basic formulas

Acres per hour = working width in feet x speed in mph / 8.25

Pounds per acre = pounds applied per minute x 60 / acres per hour

Working width equals row spacing times number of rows. For example, 8 rows at 30 inches is 20 feet.

Illustrative: 20 feet at 5 mph gives 20 x 5 / 8.25 = 12.1 acres per hour. To apply 100 pounds of product per acre you need 12.1 x 100 = 1,210 pounds per hour, or about 20 pounds per minute for the whole bar, which is 2.5 pounds per minute per row.

Step by step

  1. Measure speed over a known distance in the field conditions: 200 feet in 27 seconds gives 200 x 0.68 / 27 = 5.0 mph.
  2. Set the metering to a trial setting for the product and rate. Dry fertilizer varies with granule size and moisture, so use the chart as a start only.
  3. Catch test: With the bar stationary, or on a calibration mat, run the meter for a timed period, for example 1 minute, collect from several rows and weigh. Alternatively, drive a measured distance with collectors attached. Liquid systems: collect for a minute and measure ounces, then convert using the product's density.
  4. Calculate the rate with the formula above, using total output of all rows.
  5. Adjust the setting and repeat until the rate is within the tolerance you accept.
  6. Check row-to-row variation: large differences between rows mean plugged lines, worn parts or poor distribution. Fix before applying.

Strip placement

  • Measure depth in several locations. Typical settings depend on the soil and crop, so follow your agronomist's advice.
  • Check that the strip is located where the planter row will go. Mark and test with GPS guidance or auto-steer.
  • Confirm fertilizer outlet position: banded fertilizer too close to the seed can hurt germination. Follow the extension guidance for safe distances and rates for your crop and product.

Common errors

  • Using the controller's displayed rate without checking the weight output.
  • Calibrating at one speed and operating at another.
  • Not recalibrating when the product changes.
  • Ignoring a worn or sticky meter.

Convert nutrients correctly: product pounds x analysis percent / 100 = nutrient pounds. Follow your soil test recommendations; see the fertilizer recommendation worksheet, and compare with the spinner spreader calibration for broadcast units.

Record you can copy

FieldWhat to record
Date and fieldBar, tractor, operator
Row count and spacingWorking width in feet
Product and analysisName, percent nutrients
Speedmph measured
Meter settingDial, rpm or controller number
Output per minutePounds or ounces, by row
Calculated ratePounds product per acre
Strip depthInches, at several points

Authoritative references