Seed & Input Directory

Sprayer Boom Height and Alignment Form: Checking Pattern and Overlap

Use this form before spraying to set boom height, check that the boom is level and parallel to the target, and confirm nozzle orientation so the pattern overlaps as the nozzle maker intends.

Key points

  • Boom height controls overlap: too low leaves streaks, too high increases drift.
  • Set height from the nozzle manufacturer's chart for your nozzle angle and spacing.
  • Check the boom is level side to side and parallel to the ground or canopy, including on slopes and in turns.
  • Check that every nozzle is the right type, correctly seated and pointed straight down or at the intended angle.

How height and overlap work

A flat-fan nozzle sprays a fan with a stated included angle, such as 80 or 110 degrees. The width of the pattern at the target is approximately:

Pattern width = 2 x height x tan(half the angle)

Illustrative example: a 110-degree nozzle at 20 inches above the target gives 2 x 20 x tan(55 degrees) = 2 x 20 x 1.43 = about 57 inches. On 20-inch spacing, that pattern is about 2.9 times the spacing, so the fans overlap substantially. An 80-degree nozzle at the same height gives 2 x 20 x tan(40 degrees) = 2 x 20 x 0.84 = about 34 inches, or 1.7 times the spacing. Real patterns are narrower than the geometry because the edges of a fan carry little liquid, and the angle decreases at low pressure and with some liquids. For that reason, always follow the manufacturer's minimum recommended height for your nozzle type and spacing, usually printed on a chart or the nozzle catalogue. Keep that chart in the cab.

Setting the height

  1. Identify the nozzle series, angle and spacing; check them against the sprayer's nozzle chart.
  2. Measure from the nozzle tip to the target: the ground for fallow or pre-emergence, or the top of the canopy for post-emergence.
  3. Adjust the boom to the recommended height. Many nozzle makers specify heights for 20-inch and 30-inch spacing.
  4. Re-check after changing to a different nozzle, spacing or crop stage.

Do not go much higher than needed. Every extra few inches increases the time droplets are exposed to wind and evaporation, which raises drift. Pair this with low-drift nozzles, spray quality settings and wind-speed limits from the product label.

Checking level and alignment

  • Park on level ground with a full or consistently loaded tank and measure the height at both boom ends and at the centre. Differences of more than an inch or two merit correction.
  • Check boom hinges, bushings and suspension for play; worn parts cause bounce and lean.
  • Look at the boom from behind to see whether the line of nozzles is straight and whether a boom section has dropped.
  • On slopes and in turns, watch for the boom dipping into the ground or lifting.
  • Verify that every nozzle body is turned the same way: flat-fan nozzles commonly sit at a slight angle (about 5 to 10 degrees off the boom axis) so neighbouring fans do not collide. Follow the manufacturer's guidance. Turned or missing nozzles create streaks.

Quick pattern test

With clean water, spray a pass over a hard surface and see wet streaks, or use a patternator if available. Dry stripes, heavy stripes or an uneven edge indicate misalignment, a worn tip or a blocked screen. Swap the nozzle or fix the cause. See the nozzle wear record and re-run the sprayer calibration if nozzles changed.

Record you can copy

FieldWhat to record
Date and sprayerID
Nozzle type, angle and spacingFrom tips
Target height (manufacturer chart)Inches
Measured height: left / centre / rightInches
Boom level differenceInches
Nozzles turned or damagedNumber and position
Pattern test resultPass or fix
Action taken and by whomNotes